tlp(8) | Power Management | tlp(8) |
NAME
tlp - apply laptop power saving settings
SYNOPSIS
tlp command [parameters] [-- CONFIG_PARAM=value ... ]
DESCRIPTION
tlp applies power saving settings manually and controls battery care features.
COMMANDS
- start
- Start tlp and apply power saving profile for the actual power source. Also use to apply a changed configuration or to leave manual mode.
- bat
- Apply battery profile and enter manual mode. Manual mode means that changes to the power source will be ignored until the next reboot or tlp start is issued to resume automatic mode.
- true
- Alias for bat.
- ac
- Apply AC profile and enter manual mode. Manual mode means that changes to the power source will be ignored until the next reboot or tlp start is issued to resume automatic mode.
- false
- Alias for ac.
- usb
- Enable autosuspend for all USB devices except those excluded by default or via configuration.
- bayoff
- Turn off optical drive in UltraBay/MediaBay. The drive may be re-enabled by pulling the eject lever or pushing the media eject button on newer models.
- setcharge [start_threshold stop_threshold] [battery]
- Change battery charge thresholds temporarily. If your hardware supports only a stop threshold, set the start value to 0. Configured charge thresholds will be restored at the next boot or by using tlp setcharge again but without the threshold arguments.
- fullcharge [battery]
- Charge battery to full capacity. This is done by applying vendor presets to the charge thresholds temporarily. Configured charge thresholds will be restored at the next boot or by using tlp setcharge without the threshold arguments.
- chargeonce [battery]
- Charge battery to the stop charge threshold once. This is done by temporarily lifting the start charge threshold. The configured start charge threshold will be restored at the next boot or by using tlp setcharge without the threshold arguments.
- discharge [battery] [target_charge_level]
- Force a complete or partial discharge of the battery while on AC power.
- recalibrate [battery]
- Perform a battery recalibration while on AC power: completely discharge the battery and recharge to 100%. The latter is done by temporarily applying vendor presets to the thresholds. Configured thresholds will be restored at the next boot or by using tlp setcharge.
- diskid
- Print disk ids for configured drives.
- --version
- Print TLP version.
- -- CONFIG_PARAM=value ...
- Append configuration parameters to a command. These temporarily override the system configuration during execution of that command only and are not kept afterwards. Disclaimer: this feature exists for the sole purpose of test automation during TLP's development. It is provided as is and there is no support whatsoever.
NOTES
Availability of the above battery care commands and the possible charge threshold values always depend on laptop vendor or brand, Linux kernel version and TLP version. Check for actual availability, threshold ranges and battery names with tlp-stat -b. Follow the link in the SEE ALSO section for details.
For laptops with two batteries, the secondary battery must be specified as a command parameter in order to select it. In many cases the main battery will be BAT0, the secondary battery BAT1. When in doubt, the output of tlp-stat -b, which lists all batteries, can help.
EXAMPLES
Change thresholds of the main battery to 70 / 90% temporarily:
- tlp setcharge 70 90
Charge the secondary battery to full capacity:
- tlp fullcharge BAT1
Recalibrate the main battery:
- tlp recalibrate
FILES
/etc/tlp.conf
/etc/tlp.d/*.conf
/usr/share/tlp/defaults.conf
/run/tlp/run.conf
/etc/default/tlp
EXIT STATUS
On success, 0 is returned, a non-zero failure code otherwise.
SEE ALSO
AUTHOR
(c) 2025 Thomas Koch <linrunner at gmx.net>
2025-02-04 | TLP 1.8.0 |