ORG.BLUEZ.GATTDESCRIPTOR(5) Linux System Administration NAME org.bluez.GattDescriptor - BlueZ D-Bus GattDescriptor API documentation DESCRIPTION GATT local/server and remote/client descriptor attribute representation share the same high-level D-Bus API. Local/Server refers to GATT based descriptors exported by a plugin or an external application. Remote/Client refers to GATT descriptors exported by the peer. INTERFACE Client Service org.bluez Interface org.bluez.GattDescriptor1 Object path [variable prefix]/{hci0,hci1,...}/dev_XX_XX_XX_XX_XX_XX/serviceXX/charYYYY/descriptorZZZ Server Service unique name Interface org.bluez.GattDescriptor1 Object path freely definable Methods array{byte} ReadValue(dict flags) Issues a request to read the value of the descriptor and returns the value if the operation was successful. Possible options: uint16_t offset Read start offset in bytes. object device (server only) Device object. string link Link type (Server only). Possible values: "BR/EDR" "LE" Possible Errors: org.bluez.Error.Failed org.bluez.Error.InProgress org.bluez.Error.NotPermitted org.bluez.Error.NotAuthorized org.bluez.Error.NotSupported void WriteValue(array{byte} value, dict flags) Issues a request to write the value of the descriptor. Possible flags: uint16 offset Write start offset in bytes. uint16 mtu Exchanged MTU (Server only). object device Device path (Server only). string link Link type (Server only). Possible values: "BR/EDR" "LE" boolean prepare-authorize True if prepare authorization request. Possible Errors: org.bluez.Error.Failed org.bluez.Error.InProgress org.bluez.Error.NotPermitted org.bluez.Error.InvalidValueLength org.bluez.Error.NotAuthorized org.bluez.Error.NotSupported Properties string UUID [read-only] 128-bit descriptor UUID. object Characteristic [read-only] Object path of the GATT characteristic the descriptor belongs to. array{byte} Value [read-only, optional] The cached value of the descriptor. This property gets updated only after a successful read request, upon which a PropertiesChanged signal will be emitted. array{string} Flags [read-only] Defines how the descriptor value can be used. Possible values: "read" "write" "encrypt-read" "encrypt-write" "encrypt-authenticated-read" "encrypt-authenticated-write" "secure-read" (Server Only) "secure-write" (Server Only) "authorize" uint16 Handle [read-only] (Client Only) Descriptor handle. uint16 Handle [read-write, optional] (Server Only) Descriptor handle. When available in the server it would attempt to use to allocate into the database which may fail, to auto allocate the value 0x0000 shall be used which will cause the allocated handle to be set once registered. BlueZ October 2023 ORG.BLUEZ.GATTDESCRIPTOR(5)