NVME(1) NVMe Manual NVME(1) NAME nvme - the NVMe storage command line interface utility (nvme-cli) SYNOPSIS built-in plugin: nvme [] extension plugins: nvme [] DESCRIPTION NVM-Express is a fast, scalable host controller interface designed to address the needs for not only PCI Express based solid state drives, but also NVMe-oF(over fabrics). This nvme program is a user space utility to provide standards compliant tooling for NVM-Express drives. It was made specifically for Linux as it relies on the IOCTLs defined by the mainline kernel driver. NVME COMMANDS The utility has sub-commands for all admin and io commands defined in the specification and for displaying controller registers. There is also an option to submit completely arbitrary commands. For a list of commands available, run "nvme help". NVME CLI SUB-COMMANDS Main commands nvme-admin-passthru(1) Admin Passthrough Command nvme-compare(1) IO Compare nvme-error-log(1) Retrieve error logs nvme-flush(1) Submit flush nvme-dsm(1) Submit Data Set Management nvme-format(1) Format namespace(s) nvme-fw-activate(1) F/W Activate (in old version < 1.2) nvme-fw-commit(1) F/W Commit (in > 1.2) nvme-fw-download(1) F/W Download nvme-fw-log(1) Retrieve f/w log nvme-get-feature(1) Get Features nvme-get-log(1) Generic Get Log nvme-telemetry-log(1) Telemetry Host-Initiated Log nvme-changed-ns-list-log(1) Retrieve Changed Namespace List Log nvme-smart-log(1) Retrieve Smart Log nvme-ana-log(1) Retrieve ANA(Asymmetric Namespace Access) Log nvme-endurance-log(1) Retrieve endurance Log nvme-effects-log(1) Retrieve effects Log nvme-self-test-log(1) Retrieve Device Self-test Log nvme-get-ns-id(1) Retrieve namespace identifier nvme-help(1) NVMe CLI Help nvme-id-ctrl(1) Identify Controller nvme-id-ns(1) Identify Namespace nvme-id-nvmset(1) Identify NVM Set List nvme-id-iocs(1) Identify I/O Command Set nvme-create-ns(1) Create a new namespace nvme-delete-ns(1) Delete existing namespace nvme-attach-ns(1) Attach namespace nvme-detach-ns(1) Detach namespace nvme-io-passthru(1) IO Passthrough Command nvme-list-ns(1) List all nvme namespaces nvme-ns-descs(1) Identify Namespace Identification Descriptor nvme-list(1) List all nvme controllers nvme-list-ctrl(1) List controller in NVMe subsystem nvme-list-subsys(1) List NVMe subsystems nvme-reset(1) Reset a NVMe controller nvme-device-self-test(1) Issue Device Self-test Command nvme-read(1) Issue IO Read Command nvme-write(1) Issue IO Write Command nvme-write-zeroes(1) Issue IO Write Zeroes Command nvme-write-uncor(1) Issue IO Write Uncorrectable Command nvme-resv-acquire(1) Acquire Namespace Reservation nvme-resv-register(1) Register Namespace Reservation nvme-resv-release(1) Release Namespace Reservation nvme-resv-report(1) Report Reservation Capabilities nvme-security-recv(1) Security Receive nvme-security-send(1) Security Send nvme-dsm(1) Issue Data Set Management Command nvme-copy(1) Issue Simple Copy Command nvme-set-feature(1) Set Feature nvme-show-regs(1) Show NVMe Controller Registers nvme-discover(1) Send Get Log Page request to Discovery Controller nvme-connect-all(1) Discover and connect to all NVMe-over-Fabrics subsystems nvme-connect(1) Connect to an NVMe-over-Fabrics subsystem nvme-dim(1) Send Discovery Information Management command to a Discovery Controller nvme-disconnect(1) Disconnect from an NVMe-over-Fabrics subsystem nvme-disconnect-all(1) Disconnect from all NVMe-over-Fabrics subsystems nvme-get-property(1) Reads and shows NVMe-over-Fabrics controller property nvme-media-unit-stat-log(1) Retrieve and show the configuration and wear of media units nvme-supported-cap-config-log(1) Retrieve and show the list of Supported Capacity Configuration Descriptors nvme-boot-part-log(1) Retrieve Boot Partition Log nvme-capacity-mgmt(1) Capacity Management Command nvme-check-dhchap-key(1) Generate NVMeoF DH-HMAC-CHAP host key nvme-check-tls-key(1) Validate NVMeoF TLS PSK nvme-cmdset-ind-id-ns(1) I/O Command Set Independent Identify Namespace nvme-endurance-event-agg-log(1) Retrieve Endurance Group Event Aggregate Log nvme-fid-support-effects-log(1) Retrieve FID Support and Effects log nvme-gen-dhchap-key(1) Generate NVMeoF DH-HMAC-CHAP host key nvme-gen-hostnqn(1) Generate NVMeoF host NQN nvme-gen-tls-key(1) Generate NVMeoF TLS PSK nvme-get-lba-status(1) Get LBA Status command nvme-id-domain(1) NVMe Identify Domain List nvme-id-ns-lba-format(1) NVMe Identify Namespace for the specified LBA Format index nvme-lba-status-log(1) Retrieve LBA Status Information Log nvme-list-endgrp(1) NVMe Identify Endurance Group List nvme-ns-rescan(1) Rescans the NVME namespaces nvme-nvm-id-ctrl(1) NVMe Identify Controller NVM Command Set nvme-nvm-id-ns(1) NVMe Identify Namespace NVM Command Set nvme-nvm-id-ns-lba-format(1) NVMe Identify Namespace NVM Command Set for the specified LBA Format index nvme-persistent-event-log(1) Retrieve Persistent Event Log nvme-predictable-lat-log(1) Retrieve Predictable Latency per Nvmset Log nvme-pred-lat-event-agg-log(1) Retrieve Predictable Latency Event Aggregate Log nvme-primary-ctrl-caps(1) NVMe Identify Primary Controller Capabilities nvme-reset(1) Resets the controller nvme-rpmb(1) Replay Protection Memory Block commands nvme-sanitize-log(1) Retrieve sanitize log nvme-set-property(1) Set a property and show the resulting value nvme-show-hostnqn(1) Show NVMeoF host NQN nvme-subsystem-reset(1) Resets the subsystem nvme-supported-log-pages(1) Retrieve the Supported Log pages details nvme-verify(1) verify command nvme-show-topology(1) Show NVMe topology Plugins/Vendor extension commands nvme-intel-id-ctrl(1) Intel - NVMe Identify Controller nvme-intel-internal-log(1) Retrieve Intel device's internal log and save to file nvme-intel-lat-stats(1) Retrieve NVMe Identify Controller, return result and structure nvme-intel-market-name(1) Intel vendor specific marketing name log page nvme-intel-smart-log-add(1) NVMe Intel Additional SMART log page nvme-intel-temp-stats(1) NVMe Intel Additional SMART log page for temp stats nvme-huawei-id-ctrl(1) NVMe huawei Identify Controller nvme-huawei-list(1) List all recognized Huawei NVMe devices nvme-dera-stat(1) NVMe Dera Device status and Additional SMART log page request nvme-micron-clear-pcie-errors(1) Clears correctable PCIe correctable errors of given Micron device nvme-micron-internal-log(1) Retrieve Micron device's internal logs and save to given zip file nvme-micron-nand-stats(1) Retrieves NAND statistics of given micron device nvme-micron-pcie-stats(1) Retrieves pcie error statistics for given micron device nvme-micron-selective-download(1) Performs selective firmware download nvme-micron-smart-add-log(1) Retrieves NAND statistics nvme-micron-temperature-stats(1) Retrieves temperature information of given micron device nvme-netapp-ontapdevices(1) Display information about ONTAP devices nvme-netapp-smdevices(1) Display information for each NVMe path to an E-Series volume nvme-toshiba-clear-pcie-correctable-errors(1) Reset the PCIe correctable errors count to zero nvme-toshiba-vs-internal-log(1) Retrieve a Toshiba device's vendor specific internal log nvme-toshiba-vs-smart-add-log(1) Retrieve a Toshiba device's vendor specific extended SMART log page nvme-transcend-badblock(1) Retrieve Transcend NVMe device's bad blocks nvme-transcend-healthvalue(1) Use NVMe SMART table to analyze the health value of Transcend device nvme-virtium-show-identify(1) Show a complete detail of identify device information in json format nvme-virtium-save-smart-to-vtview-log(1) Periodically save smart attributes into a log file nvme-wdc-cap-diag(1) Retrieve WDC device's diagnostic log and save to file nvme-wdc-capabilities(1) Display WDC plugin command capabilities nvme-wdc-clear-assert-dump(1) Clears the assert dump (if present) nvme-wdc-clear-fw-activate-history(1) Clears the firmware activate history table nvme-wdc-clear-pcie-corr(1) Clears the pcie correctable errors field nvme-wdc-clear-pcie-correctable-errors(1) Clears the pcie correctable errors returned in the smart-log-add command nvme-wdc-cloud-SSD-plugin-version(1) Display WDC plugin Cloud SSD Plugin Version nvme-wdc-drive-essentials(1) Retrieve WDC device's drive essentials bin files nvme-wdc-drive-log(1) Retrieve WDC device's drive log and save to file nvme-wdc-drive-resize(1) Send NVMe WDC Resize Vendor Unique Command nvme-wdc-enc-get-log(1) Send NVMe WDC enc-get-log Vendor Unique Command nvme-wdc-get-crash-dump(1) Retrieve WDC device's crash dump nvme-wdc-get-drive-status(1) Send the NVMe WDC get-drive-status command nvme-wdc-get-latency-monitor-log(1) Display latency monitor log page data in human readable format nvme-wdc-get-pfail-dump(1) Retrieve WDC device's pfail crash dump nvme-wdc-id-ctrl(1) Send NVMe Identify Controller, return result and structure nvme-wdc-log-page-directory(1) Retrieves the list of Log IDs supported by the drive nvme-wdc-namespace-resize(1) Resizes the device's namespace nvme-wdc-purge-monitor(1) Send NVMe WDC Purge-Monitor Vendor Unique Command nvme-wdc-purge(1) Send NVMe WDC Purge Vendor Unique Command nvme-wdc-smart-add-log(1) Send NVMe WDC smart add log Vendor Unique Command nvme-wdc-vs-drive-info(1) Send the NVMe WDC vs-drive-info command nvme-wdc-vs-error-reason-identifier(1) Retrieve WDC device's telemetry log error reason identifier field nvme-wdc-vs-fw-activate-history(1) Execute NVMe WDC vs-fw-activate-history Vendor Unique Command nvme-wdc-vs-internal-log(1) Retrieve WDC device's internal firmware log and save to file nvme-wdc-vs-nand-stats(1) Send NVMe WDC vs-nand-stats Vendor Unique Command nvme-wdc-vs-telemetry-controller-option(1) Disable/Enable the controller initiated option of the telemetry log page nvme-wdc-vs-temperature-stats(1) Display temperature-related statistics nvme-zns-changed-zone-list(1) Retrieve Changed Zone log for the given device nvme-zns-close-zone(1) Closes one or all zones nvme-zns-finish-zone(1) Finishes one or all zones nvme-zns-id-ctrl(1) Send NVMe Zoned Command Set Identify Controller nvme-zns-id-ns(1) Send NVMe Zoned Command Set Identify Namespace nvme-zns-offline-zone(1) Offlines one or all zones nvme-zns-open-zone(1) Opens one or all zones nvme-zns-report-zones(1) Retrieve and display the Report Zones data structure nvme-zns-reset-zone(1) Resets one or all zones nvme-zns-set-zone-desc(1) Set extended descriptor data for a zone nvme-zns-zone-append(1) Send an NVMe write command, provide results nvme-zns-zone-mgmt-recv(1) Zone Management Receive command nvme-zns-zone-mgmt-send(1) Zone Management Send command nvme-zns-zrwa-flush-zone(1) Flush LBAs associated with a ZRWA to a zone nvme-inspur-nvme-vendor-log(1) NVMe Inspur Device Vendor log page request RETURNS All commands will behave the same, they will return 0 on success and 1 on failure. FURTHER DOCUMENTATION See the freely available references on the Official NVM-Express Site[1]. AUTHORS This is written and maintained by Keith Busch[2]. REPORTING BUGS Patches and issues may be submitted to the official repository at https://github.com/linux-nvme/nvme-cli or the Linux NVMe mailing list linux-nvme[3] NVME Part of the nvme suite NOTES 1. Official NVM-Express Site http://nvmexpress.org 2. Keith Busch mailto:kbusch@kernel.org 3. linux-nvme mailto:linux-nvme@lists.infradead.org NVMe 02/16/2024 NVME(1)