| NVME-ID-CTRL-LIST(1) | NVMe Manual | NVME-ID-CTRL-LIST(1) |
NAME
nvme-id-ctrl-list - Send NVMe Identify List Controllers, return result and structure
SYNOPSIS
nvme [<global-options>] id ctrl-list <device> [--cntid=<cntid> | -c <cntid>]
[--namespace-id=<nsid> | -n <nsid>]
DESCRIPTION
For the NVMe device given, sends an identify command for controller list and provides the result and returned structure. This uses either mode 12h or 13h depending on the requested namespace identifier.
The <device> parameter is mandatory and may be either the NVMe character device (ex: /dev/nvme0), or a namespace block device (ex: /dev/nvme0n1). The starting controller in the list always begins with 0 unless the '--cntid' option is given to override.
On success, the controller array is printed for each index and controller identifier.
OPTIONS
-c <cntid>, --cntid=<cntid>
-n <nsid>, --namespace-id=<nsid>
GLOBAL OPTIONS
The following options are defined at the top-level nvme command and are available to this subcommand:
--dry-run
--no-ioctl-probing
--no-retries
-o <fmt>, --output-format=<fmt>
--output-format-version=<version>
--timeout=<ms>
-v, --verbose
These options can also be set as machine-wide defaults in nvme-cli.conf(5). A command-line flag always overrides the file.
EXAMPLES
No examples yet.
NVME
Part of the nvme-user suite
| 09/07/2026 | NVMe |