NVME-CONFIG-SHOW(1) NVMe Manual NVME-CONFIG-SHOW(1) NAME nvme-config-show - Show the resolved NVMe-oF INI connection configuration SYNOPSIS nvme [] config show [--config= | -J ] DESCRIPTION Reads the NVMe-oF INI connection configuration file used by nvme connect-all and nvme discover, and prints every configured connection entry. The INI format is documented at https://github.com/linux-nvme/nvme-cli/blob/master/libnvme/design/CONFIG.md By default, the file at /etc/nvme/nvme-fabrics.conf is read. Use --config to show a file at a different path instead. In the default and tabular output formats, each entry is rendered as the equivalent command line that would establish it: nvme connect-all for a Discovery Controller entry, nvme connect for an I/O Controller entry, preceded by a comment naming the entry's source (which file/section it came from). The json output format instead reports each entry's fields individually (transport, address, NQN, host identity, and any extra connect parameters). This command never touches the network: addressing is shown exactly as configured, with no hostname resolution attempted. A persona with no hostnqn/hostid set is shown without those fields rather than the system default it would resolve to at connect time, since showing a concrete value here would suggest a fixed identity the configuration doesn't actually pin. OPTIONS -J , --config= Show this INI file instead of the default /etc/nvme/nvme-fabrics.conf. GLOBAL OPTIONS The following options are defined at the top-level nvme command and are available to this subcommand: --dry-run Print the command that would be executed, but do not actually execute it. --no-ioctl-probing Disable probing for 64-bit IOCTL support. --no-retries Disable retry logic on transient errors. -o , --output-format= Set the reporting format to normal, tabular, 'json, or binary. Only one output format may be used at a time. --output-format-version= Select the output format version. Version 1 uses the original field naming, while version 2 (default) provides more consistent and script-friendly field names. --timeout= Set the timeout for the command in milliseconds. -v, --verbose Increase the level of detail in the output. May be specified multiple times to further increase verbosity. These options can also be set as machine-wide defaults in nvme-cli.conf(5). A command-line flag always overrides the file. EXAMPLES o Show the system's resolved configuration: # nvme config show # nvme0: Discovery Controller nvme connect-all --transport=tcp --traddr=192.168.1.10 --trsvcid=8009 # nvme1: I/O Controller nvme connect --transport=tcp --traddr=192.168.1.10 --trsvcid=4420 \ --nqn=nqn.2014-08.org.nvmexpress:uuid:6a4f5e3e-... o Show a configuration file at a non-default path, as JSON: $ nvme config show --config /tmp/nvme-fabrics.conf -o json SEE ALSO nvme-config-validate(1) nvme-config-convert(1) nvme-config-status(1) nvme-connect-all(1) nvme-discover(1) https://github.com/linux-nvme/nvme-cli/blob/master/libnvme/design/CONFIG.md NVME Part of the nvme-user suite NVMe 09/07/2026 NVME-CONFIG-SHOW(1)