NHS_SER(8) NUT Manual NHS_SER(8) NAME nhs_ser - Driver for NHS Nobreaks, senoidal line, with serial port SYNOPSIS nhs_ser -h nhs_ser -a UPS_NAME [OPTIONS] Note This man page only documents the hardware-specific features of the nhs_ser driver. For information about the core driver, see nutupsdrv(8). SUPPORTED HARDWARE nhs_ser supports numerous UPS models made by NHS Sistemas Eletronicos LTDA and marketed in Brazil. They feature a serial port and a binary wire protocol. Note Currently this driver only builds on Linux. This is expected to change in future revisions of the code. EXTRA ARGUMENTS This driver also supports the following optional settings: baud=num Set the value of serial port baud rate (default: 2400) ah=num Battery discharge capacity in Ampere/hour. va=num Nobreak NOMINAL POWER in VA. pf=num Power Factor to use in calculations of battery time (default: 0.90). vin_low_warn_perc=num Voltage In Percentage to calculate warning low level (default: 2.00). vin_low_crit_perc=num Voltage In Percentage to calculate critical low level (default: 2.00). vin_high_warn_perc=num Voltage In Percentage to calculate warning high level (default: 2.00). vin_high_crit_perc=num Voltage In Percentage to calculate critical high level (default: 2.00). numbatteries=num Num Batteries (override value from nobreak). vbat=num Battery Voltage (default: 12.00). debug_pkt_raw Optional flag to enable debug logging of packet bytes. debug_pkt_data Optional flag to enable debug logging of data packet decoding. debug_pkt_hwinfo Optional flag to enable debug logging of hwinfo packet decoding. AUTHORS Lucas Willian Bocchi SEE ALSO The core driver: nutupsdrv(8) Internet resources: The NUT (Network UPS Tools) home page: https://www.networkupstools.org/historic/v2.8.3/ Network UPS Tools 2.8.3 05/29/2025 NHS_SER(8)