MICROSOL-APC(8) NUT Manual MICROSOL-APC(8) NAME microsol-apc - Driver for APC Back-UPS BR UPS equipment SYNOPSIS microsol-apc -h microsol-apc -a UPS_NAME [OPTIONS] Note This man page only documents the hardware-specific features of the microsol-apc driver. For information about the core driver, see nutupsdrv(8). SUPPORTED HARDWARE This driver supports the following UPS models: o APC Back-UPS BZ1500-BR o APC Back-UPS BZ2200I-BR o APC Back-UPS BZ2200BI-BR In 2009, Schneider Electric acquired Microsol Technologies, and by 2012, the entire Microsol line was being sold under the APC brand. This driver supports these newer, APC-branded models. Older equipment should use solis(8). EXTRA ARGUMENTS This driver support the following extra optional settings in the ups.conf(5). battext = n - (default = 0, no extra battery, where n = Ampere*hour ) prgshut = 1 - (default = 0, no programmable shutdown ) COMMANDS o shutdown.return - Shut down in .3 minutes and restart in .3 minutes o shutdown.stayoff - Shut down in .3 minutes and do not return ISSUES For other APC-Microsol models, the reported voltages, currents and power will be incorrect, as the communication protocol reports unprocessed data instead of real values, needing model-specific post-processing by the driver. Monitoring of UPS state (on-battery/on-line, critical battery) should work for other models, but is untested. AUTHORS o Ygor A. S. Regados o Roberto P. Velloso o Silvino B. Magalhaes SEE ALSO The core driver: nutupsdrv(8) Internet resources: The NUT (Network UPS Tools) home page: https://www.networkupstools.org/ Network UPS Tools 2.8.2 05/20/2024 MICROSOL-APC(8)