NVME-RESV-NOTIF-L(1) | NVMe Manual | NVME-RESV-NOTIF-L(1) |
NAME
nvme-resv-notif-log - Send NVMe Reservation Notification log page request, return result and log
SYNOPSIS
nvme resv-notif-log <device> [--output-format=<fmt> | -o <fmt>] [--verbose | -v]
DESCRIPTION
Retrieves NVMe Reservation Notification log page from an NVMe device and provides the returned structure.
The <device> parameter is mandatory and may be either the NVMe character device (ex: /dev/nvme0), or a namespace block device (ex: /dev/nvme0n1).
On success, the returned Reservation Notification log structure may be returned in one of several ways depending on the option flags; the structure may parsed by the program and printed in a readable format or the raw buffer may be printed to stdout for another program to parse.
OPTIONS
-o <fmt>, --output-format=<fmt>
Set the reporting format to normal, json or
binary. Only one output format can be used at a time.
-v, --verbose
Increase the information detail in the output.
EXAMPLES
•Get the Reservation Notification log and print it
in a human readable format:
# nvme resv-notif-log /dev/nvme0
•Print the output in json format:
# nvme resv-notif-log /dev/nvme0 -o json
NVME
Part of the nvme-user suite
08/07/2024 | NVMe |